Open hardware

M3-CRETE

The default M3-2 design uses four Tr8×2 lead screws to lift the gantry, one at each corner. GT2 belts drive X and Y. Qualified teams can inspect the bill of materials and work-in-progress build reference. Field suitability remains unverified. Building or operating the system requires independent engineering, electrical, safety, and commissioning review.

CAD rendering of the M3-CRETE printer frame and gantry
M3-2 nominal design envelope
2m³
X 2 m × Y 1 m × Z 1 m
Form Factor
Pallet48×40 in
Architecture
CartesianDual-Y
License
CERN-OHLW-2.0
Status
DevActive
// 01
Motion system

A pallet-scale concrete/paste-printer development design based on a scaled Cartesian dual-Y belt-pinion architecture with quad-Z self-tramming. The published concept uses a lightweight printhead (~1.5 kg) and V-groove motion system. Dust, weather, duty-cycle, guarding, electrical, and field performance require independent validation. BOM prices are planning references, not a guaranteed build cost.

// 02
Design files

The public CAD and BOM are available for inspection and modification. Any build or material selection requires the builder's own safety review and validation.

// 03
Materials research with CEMFORGE™

CEMFORGE can organize material evidence and identify gaps for controlled research planning. It does not supply a production-approved M3-CRETE mix, and modeled outputs do not establish pumpability, printability, buildability, strength, durability, structural adequacy, or field suitability. Actual materials, equipment, and conditions require independent laboratory and project review.

// 04
Get Involved

The project is in active development. CAD files and BOM are published, with build guides and documentation added to the GitHub repository as they are reviewed. Publication does not mean a design has been certified or field-validated. Watch the repository, open an issue, or start a discussion for design feedback, build reports, or technical questions.

// SAFETY
Qualified Technical Use

M3-CRETE is not a casual hobby kit, finished certified printer, or jobsite-ready electrical product. It is intended for qualified technical users, R&D labs, supervised institutional programs, and experienced builders. Any AC mains wiring, control-box integration, grounding, disconnects, emergency-stop power circuits, facility connection, inspection, or code compliance work must be performed by qualified personnel, a licensed electrician where required, or a qualified control-panel shop. Public project files identify interfaces and components; they are not AC mains wiring instructions.